Eaton 103007415-5400 Bypass Module - 103007415-5400

Eaton 103007415-5400 Bypass Module - 103007415-5400

$13,078.00
Availability:
Out of stock
Product type:

Eaton 103007415-5400 Bypass Module

UPC 355334067008
60 kW
General Information
Manufacturer: Eaton Corporation
Manufacturer Part Number: 103007415-5400
Manufacturer Website Address: http://www.eaton.com/EatonCom/Markets/NorthAmerica
Brand Name: Eaton
Product Model: 103007415-5400
Product Name: 103007415-5400 Bypass Module
Marketing Information:

The Eaton BladeUPS Maintenance Bypass Module (MBM) is a fully featured maintenance bypass designed to transfer power from a fully populated 60 kW N+1 BladeUPS system into bypass, allowing maintenance and service to be performed on a de-energized BladeUPS cabinet without affecting power to the critical load. Factory installed 225A @208V (150A @400V) maintenance bypass breaker (MBB), UPS Input Breaker (UIB) and UPS output breaker (UOB). A breaker interlock bar ensures the proper sequencing of the MBB and UOB when bringing the BladeUPS cabinet off and online. The MBM's Activate UPS Bypass Mode switch simplifies the process of going to bypass even further by providing a single point to transfer all BladeUPS units into bypass, and ready the system for the transfer of power.

Product Type: Bypass Module
Power Description
Load Capacity (VA): 60 kW
Output Voltage:
  • 230 V AC
  • 400 V AC
Physical Characteristics
Color Family: Black
Product Color: Black
Form Factor: Rack-mountable
Height: 10.50" (266.70 mm)
Width: 17.30" (439.42 mm)
Depth: 29.60" (751.84 mm)
Weight (Approximate): 34.47 kg
Miscellaneous
Additional Information:
  • Type: Three-breaker, manual interlock
  • Input & Output Cabling: Top and bottom entry
  • UPS interface: Activate UPS bypass mode switch
  • Breaker Frame: 225A
  • Trip rating: 150A
  • Breaker kAIC rating: 25kA @ 480V
  • Building interface: REPO, 120 V external contact required 1A/1B Aux switch on all breakers

Indicator Lamps:

  • UPS on Bypass
  • AC Power to bypass
  • AC Power from UPS
  • AC Power to loads
Compatibility:

Eaton BladeUPS

Country of Origin: United States
Stay ON Forever

Protects Your Device From Power Outage & Blackout

Express Shipping

Canada Wide Discounted Shipping

OEM Standard

Long Lasting Powerful Batteries with 1 year warranty

Hassle Free Returns

Request RMA and Get Refunded Within 3 Days

Technical Support

Get Free Technical Support & Installation Guide

Technical Support

Get Free Technical Support & Installation Guide

Eaton 103007415-5400 Bypass Module

UPC 355334067008
60 kW
General Information
Manufacturer: Eaton Corporation
Manufacturer Part Number: 103007415-5400
Manufacturer Website Address: http://www.eaton.com/EatonCom/Markets/NorthAmerica
Brand Name: Eaton
Product Model: 103007415-5400
Product Name: 103007415-5400 Bypass Module
Marketing Information:

The Eaton BladeUPS Maintenance Bypass Module (MBM) is a fully featured maintenance bypass designed to transfer power from a fully populated 60 kW N+1 BladeUPS system into bypass, allowing maintenance and service to be performed on a de-energized BladeUPS cabinet without affecting power to the critical load. Factory installed 225A @208V (150A @400V) maintenance bypass breaker (MBB), UPS Input Breaker (UIB) and UPS output breaker (UOB). A breaker interlock bar ensures the proper sequencing of the MBB and UOB when bringing the BladeUPS cabinet off and online. The MBM's Activate UPS Bypass Mode switch simplifies the process of going to bypass even further by providing a single point to transfer all BladeUPS units into bypass, and ready the system for the transfer of power.

Product Type: Bypass Module
Power Description
Load Capacity (VA): 60 kW
Output Voltage:
  • 230 V AC
  • 400 V AC
Physical Characteristics
Color Family: Black
Product Color: Black
Form Factor: Rack-mountable
Height: 10.50" (266.70 mm)
Width: 17.30" (439.42 mm)
Depth: 29.60" (751.84 mm)
Weight (Approximate): 34.47 kg
Miscellaneous
Additional Information:
  • Type: Three-breaker, manual interlock
  • Input & Output Cabling: Top and bottom entry
  • UPS interface: Activate UPS bypass mode switch
  • Breaker Frame: 225A
  • Trip rating: 150A
  • Breaker kAIC rating: 25kA @ 480V
  • Building interface: REPO, 120 V external contact required 1A/1B Aux switch on all breakers

Indicator Lamps:

  • UPS on Bypass
  • AC Power to bypass
  • AC Power from UPS
  • AC Power to loads
Compatibility:

Eaton BladeUPS

Country of Origin: United States
Here is the Manual Guide

ORDER PROCESSING

We ship from Toronto to Worldwide.
We process orders within 1-2 business days (excluding weekends and holidays).
Pre-ordered items are processed within 2-3 business days of arrival in stock.

Successfully placed orders will receive an e-mail confirmation with the order details.
If you do not receive an e-mail, please check your spam filter or contact us for confirmation.

If you need any assistance with your order, please contact us immediately at support@upsandbattery.com. We will not be able to make changes to your order after it has shipped.

Please review and ensure that you have entered the correct address. We are not responsible for non-delivery due to errors in the address that you provide. If an order is returned due to an incorrect address, we will refund the original order (excluding the shipping fee) and ask that you re-submit your order.

Your credit card information is safe with us. We accept most major credit, debit, and prepaid cards, including Visa, MasterCard, American Express, Discover, JCB, and Diners Club International, PayPal, Google Pay and Apple Pay.