UPC N/A
Managed - Hubbell CS8365C - 30 x IEC 60320 C13, 6 x IEC 60320 C19 - 200 V AC, 208 V AC, 220 V AC, 230 V AC, 240 V AC - Overload Protection - Network (RJ-45) - 10 ft Cord Length - 0U - Vertical - Rack-mountable - TAA Compliant
General Information
Manufacturer: Tripp Lite by Eaton
Manufacturer Part Number: PDU3EVSR1H50D
Manufacturer Website Address: https://tripplite.eaton.com/
Brand Name: Tripp Lite by Eaton
Product Model: PDU3EVSR1H50
Product Name: PDU3EVSR1H50 36-Outlets PDU
Marketing Information:

3-Phase Switched PDU Distributes, Monitors and Manages Network-Grade Power
Recommended for data centers, network service providers and large enterprises, this managed PDU with built-in network interface provides advanced network control and remote power monitoring with the ability to turn on, turn off, reboot or lock out power to each outlet. You can more efficiently manage network power consumption, maintain proper load balance and remotely reboot locked network items without having to visit the site. Reducing the number of on-site visits can help lower the cost of data center maintenance, thus lowering the 0U PDU's total cost of ownership.

36 Outlets Dispense AC Power to Connected Equipment
During normal operation, 36 individually controllable outlets-30 C13 and six C19-in three load banks distribute AC power to rack equipment. Each 200-240V outlet is accompanied by an LED that illuminates when the outlet is ramped up and ready to be used. The outlets and banks can be individually monitored to ensure proper load levels and load balancing.

IsoBreaker™ Technology Helps Maintain Critical Uptime During Overloads
Innovative IsoBreaker technology prevents the need to power down multiple devices when surges occur. In the event of a power surge due to an overload at an individual outlet, the load bank's circuit breaker trips only that outlet instead of the entire bank. This helps maintain uptime of servers and other critical equipment, avoiding a costly work stoppage.

Sophisticated Power Monitoring Includes THDv Waveform Capture
The THDv waveform capture feature is ideal for installations in which highly specific input voltage distortion measurements are critical, such as data centers, hospitals and airports. It identifies and captures the PDU input voltage quality by taking a 200ms waveform snapshot that triggers based on a THDv criteria. The THDv waveform capture trigger will capture 100ms before and 100ms after the trigger criteria. This helps provide precise input readings and accurately report line noise to help you diagnose power problems and avoid future downtime.

Built-In GbE-Capable Network Management Card Allows Remote Access 24/7
The built-in network interface with the latest version of PowerAlert® Device Manager firmware (PADM20) provides enhanced remote management capabilities, including customizable dashboard graphs to fit user preferences. The PADM20 upgrade and PowerAlert Element Manager (PAEM) software form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations. PADM20's Auto Probe feature allows a PDU with switched loads to automatically reboot devices if a network communication failure is detected. This preserves uptime and minimizes the time and expense associated with on-site support.

Color Touchscreen LCD Offers Important Data at a Glance
An easy-to-navigate color touchscreen LCD reports a detailed analysis of PDU input/output data per phase, per bank and per outlet. It also provides information on energy consumption and peak power demand. It can generate a unique QR code to allow read-only access to the PDU via mobile device. If an EnviroSense2 module (sold separately) is connected to the PDU, the LCD also displays its status and environmental data, such as temperature and humidity.

Product Type: PDU
Technical Information
PDU Type: Managed
Phase: Three Phase
Plug/Connector Type: Hubbell CS8365C
Receptacle Type:
  • IEC 60320 C13
  • IEC 60320 C19
Receptacle Detail:
  • 30 x IEC 60320 C13
  • 6 x IEC 60320 C19
Protection Type: Overload Protection
Features: LCD Display
Load Capacity (Watt): 12.60 kW
Power Description
Input Voltage:
  • 200 V AC
  • 208 V AC
  • 220 V AC
  • 230 V AC
  • 240 V AC
Output Voltage Range: 200 V AC - 240 V AC
Input Current: 35 A
Circuit Breaker: Yes
Management
Remote Outlet Switching: Yes
Interfaces/Ports
Network (RJ-45): Yes
Physical Characteristics
Color Family: Black
Product Color: Black
Mounting Orientation: Vertical
Mount Type: Rack-mountable
Rack Height: 0U
Cord Length: 10 ft
Height: 70" (1778 mm)
Width: 2.17" (55.12 mm)
Depth: 3.11" (78.99 mm)
Weight (Approximate): 9.40 kg
Environmental Conditions
Minimum Operating Temperature: 32°F (0°C)
Maximum Operating Temperature: 140°F (60°C)
Minimum Storage Temperature: 5°F (-15°C)
Maximum Storage Temperature: 158°F (70°C)
Miscellaneous
Package Contents:
  • PDU3EVSR1H50 36-Outlets PDU
  • Configuration cable
  • Rack-mounting hardware
  • Spare mounting buttons
  • PDUMVROTATEBRKT mounting bracket accessory
  • Owner's manual
  • Application/Usage:
    • IT Equipment
    • Data Center
    Certifications & Standards:
  • CAN/CSA C22.2
  • UL 62368-1
  • FCC Part 15 Class A
  • TAA Compliant: Yes
    Environmental Compliance: Restriction of Hazardous Substances (RoHS)
    Warranty
    Limited Warranty: 2 Year
    Stay ON Forever

    Protects Your Device From Power Outage & Blackout

    Express Shipping

    Canada Wide Discounted Shipping

    OEM Standard

    Long Lasting Powerful Batteries with 1 year warranty

    Hassle Free Returns

    Request RMA and Get Refunded Within 3 Days

    Technical Support

    Get Free Technical Support & Installation Guide

    Technical Support

    Get Free Technical Support & Installation Guide

    Tripp Lite by Eaton PDU3EVSR1H50 36-Outlets PDU

    UPC N/A
    Managed - Hubbell CS8365C - 30 x IEC 60320 C13, 6 x IEC 60320 C19 - 200 V AC, 208 V AC, 220 V AC, 230 V AC, 240 V AC - Overload Protection - Network (RJ-45) - 10 ft Cord Length - 0U - Vertical - Rack-mountable - TAA Compliant
    General Information
    Manufacturer: Tripp Lite by Eaton
    Manufacturer Part Number: PDU3EVSR1H50D
    Manufacturer Website Address: https://tripplite.eaton.com/
    Brand Name: Tripp Lite by Eaton
    Product Model: PDU3EVSR1H50
    Product Name: PDU3EVSR1H50 36-Outlets PDU
    Marketing Information:

    3-Phase Switched PDU Distributes, Monitors and Manages Network-Grade Power
    Recommended for data centers, network service providers and large enterprises, this managed PDU with built-in network interface provides advanced network control and remote power monitoring with the ability to turn on, turn off, reboot or lock out power to each outlet. You can more efficiently manage network power consumption, maintain proper load balance and remotely reboot locked network items without having to visit the site. Reducing the number of on-site visits can help lower the cost of data center maintenance, thus lowering the 0U PDU's total cost of ownership.

    36 Outlets Dispense AC Power to Connected Equipment
    During normal operation, 36 individually controllable outlets-30 C13 and six C19-in three load banks distribute AC power to rack equipment. Each 200-240V outlet is accompanied by an LED that illuminates when the outlet is ramped up and ready to be used. The outlets and banks can be individually monitored to ensure proper load levels and load balancing.

    IsoBreaker™ Technology Helps Maintain Critical Uptime During Overloads
    Innovative IsoBreaker technology prevents the need to power down multiple devices when surges occur. In the event of a power surge due to an overload at an individual outlet, the load bank's circuit breaker trips only that outlet instead of the entire bank. This helps maintain uptime of servers and other critical equipment, avoiding a costly work stoppage.

    Sophisticated Power Monitoring Includes THDv Waveform Capture
    The THDv waveform capture feature is ideal for installations in which highly specific input voltage distortion measurements are critical, such as data centers, hospitals and airports. It identifies and captures the PDU input voltage quality by taking a 200ms waveform snapshot that triggers based on a THDv criteria. The THDv waveform capture trigger will capture 100ms before and 100ms after the trigger criteria. This helps provide precise input readings and accurately report line noise to help you diagnose power problems and avoid future downtime.

    Built-In GbE-Capable Network Management Card Allows Remote Access 24/7
    The built-in network interface with the latest version of PowerAlert® Device Manager firmware (PADM20) provides enhanced remote management capabilities, including customizable dashboard graphs to fit user preferences. The PADM20 upgrade and PowerAlert Element Manager (PAEM) software form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations. PADM20's Auto Probe feature allows a PDU with switched loads to automatically reboot devices if a network communication failure is detected. This preserves uptime and minimizes the time and expense associated with on-site support.

    Color Touchscreen LCD Offers Important Data at a Glance
    An easy-to-navigate color touchscreen LCD reports a detailed analysis of PDU input/output data per phase, per bank and per outlet. It also provides information on energy consumption and peak power demand. It can generate a unique QR code to allow read-only access to the PDU via mobile device. If an EnviroSense2 module (sold separately) is connected to the PDU, the LCD also displays its status and environmental data, such as temperature and humidity.

    Product Type: PDU
    Technical Information
    PDU Type: Managed
    Phase: Three Phase
    Plug/Connector Type: Hubbell CS8365C
    Receptacle Type:
    • IEC 60320 C13
    • IEC 60320 C19
    Receptacle Detail:
    • 30 x IEC 60320 C13
    • 6 x IEC 60320 C19
    Protection Type: Overload Protection
    Features: LCD Display
    Load Capacity (Watt): 12.60 kW
    Power Description
    Input Voltage:
    • 200 V AC
    • 208 V AC
    • 220 V AC
    • 230 V AC
    • 240 V AC
    Output Voltage Range: 200 V AC - 240 V AC
    Input Current: 35 A
    Circuit Breaker: Yes
    Management
    Remote Outlet Switching: Yes
    Interfaces/Ports
    Network (RJ-45): Yes
    Physical Characteristics
    Color Family: Black
    Product Color: Black
    Mounting Orientation: Vertical
    Mount Type: Rack-mountable
    Rack Height: 0U
    Cord Length: 10 ft
    Height: 70" (1778 mm)
    Width: 2.17" (55.12 mm)
    Depth: 3.11" (78.99 mm)
    Weight (Approximate): 9.40 kg
    Environmental Conditions
    Minimum Operating Temperature: 32°F (0°C)
    Maximum Operating Temperature: 140°F (60°C)
    Minimum Storage Temperature: 5°F (-15°C)
    Maximum Storage Temperature: 158°F (70°C)
    Miscellaneous
    Package Contents:
  • PDU3EVSR1H50 36-Outlets PDU
  • Configuration cable
  • Rack-mounting hardware
  • Spare mounting buttons
  • PDUMVROTATEBRKT mounting bracket accessory
  • Owner's manual
  • Application/Usage:
    • IT Equipment
    • Data Center
    Certifications & Standards:
  • CAN/CSA C22.2
  • UL 62368-1
  • FCC Part 15 Class A
  • TAA Compliant: Yes
    Environmental Compliance: Restriction of Hazardous Substances (RoHS)
    Warranty
    Limited Warranty: 2 Year
    Here is the Manual Guide

    ORDER PROCESSING

    We ship from Toronto to Worldwide.
    We process orders within 1-2 business days (excluding weekends and holidays).
    Pre-ordered items are processed within 2-3 business days of arrival in stock.

    Successfully placed orders will receive an e-mail confirmation with the order details.
    If you do not receive an e-mail, please check your spam filter or contact us for confirmation.

    If you need any assistance with your order, please contact us immediately at support@upsandbattery.com. We will not be able to make changes to your order after it has shipped.

    Please review and ensure that you have entered the correct address. We are not responsible for non-delivery due to errors in the address that you provide. If an order is returned due to an incorrect address, we will refund the original order (excluding the shipping fee) and ask that you re-submit your order.

    Your credit card information is safe with us. We accept most major credit, debit, and prepaid cards, including Visa, MasterCard, American Express, Discover, JCB, and Diners Club International, PayPal, Google Pay and Apple Pay.