UPC 0037332241719
4U Rack/Tower - 3 Hour Recharge - 5 Minute Stand-by - 230 V AC Input - 120 V AC, 208 V AC Output - Single Phase - Serial Port - 12 x NEMA 5-15/20R, 6 x NEMA 6-15/20R, 2 x NEMA L6-20R
General Information
Manufacturer: Tripp Lite by Eaton
Manufacturer Part Number: SU3000LCD2UHVTF
Manufacturer Website Address: https://tripplite.eaton.com/
Brand Name: Tripp Lite by Eaton
Product Line: SmartOnline
Product Model: SU3000LCD2UHVTF
Product Name: SmartOnline SU3000LCD2UHVTF 3KVA Rack/Tower UPS
Marketing Information:

2U Double-Conversion UPS Protects Equipment against Damage, Downtime and Data Loss

This 208V and 120V 60 Hz UPS system maintains perfect output by converting AC input to DC, then reconverting UPS output to fully regulated sine wave AC with +/-2% voltage regulation in both on-line and battery modes. Featuring a 2.7kW capacity, high 0.9 power factor, 570 joules of surge suppression, true on-line operation with pure sine wave output and zero transfer time in on-line double-conversion mode, the SmartOnline® SU3000LCD2UHVTF double-conversion UPS provides the highest level of AC power protection and battery backup for critical network closet, computer room and data center equipment. With the included 2U step-down transformer, this 3kVA UPS system can support both low- and high-voltage equipment.

Set Power Strategies to Reflect Your Protection Priorities

Pick your power strategy, from precise power for sensitive systems to the highest possible electrical efficiency, while ensuring 100% uptime. Choose from four selectable strategies: Max Efficiency, Max Quality, Frequency Regulation and Auto Adaptive, which automatically offers increased efficiency when utility power conditions are good and enhanced power quality when power conditions are poor.

Individually Controllable Load Banks Let You Access and Control Outlets Remotely

The UPS and transformer combined feature 20 outlets in total-12 unswitched NEMA 5-15/20R on the transformer, six NEMA 6-15/20R on the UPS and one unswitched NEMA L6-20R on each. Four NEMA 6-15/20R outlets are split into two switchable load banks, allowing you to reboot select components or shed loads remotely.

Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages

The field-replaceable, hot-swappable internal battery provides 13.5 minutes of support at half load (1350W) and five minutes at full load (2700W), keeping protected equipment operational through power failures. For mission-critical applications demanding scalable extended runtime, the UPS supports "smart" external battery packs, such as Tripp Lite's BP72V18-2US (sold separately). Both the internal batteries and sensor-enabled external battery packs are automatically sensed and configured during installation and replacement to offer accurate remaining runtime during outages and battery-age notifications. The intelligent battery management system with temperature-compensated charging extends battery life.

Automatic Bypass Maintains Utility Output During Fault Conditions

Auto-bypass mode keeps connected equipment powered and operational, even during UPS fault conditions.

Automatically Turns Back On When Power Is Restored

Battery-independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement.

Intuitive Front-Panel Interface for Convenient UPS Operation and Monitoring

The front-panel LCD screen reports UPS operating mode, detailed UPS status and site-power information, as well as a variety of advanced UPS setup and configuration options. LEDs indicate AC input/output, battery and fault status.

Advanced Communications Ports Allow for Automatic Saves and Shutdowns

RS-232 and HID-compliant USB ports connect to a computer running Tripp Lite's free downloadable PowerAlert® software to enable safe unattended file saves and system shutdown in case of a prolonged power failure. An EPO port connects the UPS to a contact closure switch to enable emergency inverter shutdown. Cables are included.

Product Type: Double Conversion Online UPS
Technical Information
Plug/Connector Type: NEMA L6-20P
Receptacle Type:
  • NEMA 5-15/20R
  • NEMA 6-15/20R
  • NEMA L6-20R
Receptacle Detail:
  • 12 x NEMA 5-15/20R
  • 6 x NEMA 6-15/20R
  • 2 x NEMA L6-20R
Transfer Time: 0 ns
EMI/RFI Noise Filter: Yes
Phase: Single Phase
Energy Saving: High Efficiency Economy Mode Operation; Individually Controllable Load Banks
Application/Usage:
  • Mission Critical Equipment
  • Server
  • Network Equipment
  • Data Center
  • Computer Room
  • Network Closet
Power Description
Load Capacity (VA): 3 kVA
Load Capacity (Watt): 2.70 kW
Input Voltage: 230 V AC
Output Voltage:
  • 120 V AC
  • 208 V AC
Output Frequency: 60 Hz
Waveform Type: Pure Sine Wave
Surge Energy Rating: 570 J
Management
Network Management: SNMP/DB9/USB
Alarm:
  • Power Failure
  • Low Battery
  • Overload
  • Fault
Controls/Indicators
Status Indicators:

4 Front Panel LEDs:

  • AC Input (Green)
  • AC Output (Green)
  • Battery (Yellow)
  • Fault (Red)
Interfaces/Ports
Serial Port: Yes
EPO Port: Yes
USB (HID Compliant) Port: Yes
Battery Information
DC System Voltage: 72 V DC
Backup/Run Time (Full Load): 5 Minute
Backup/Run Time (Half Load): 13.50 Minute
Typical Battery Recharge Time: 3 Hour
Hot Swappable: Yes
Replaceable Battery: Yes
Environmental Conditions
Maximum Operating Temperature: 104°F (40°C)
Storage Temperature: 5°F (-15°C) - 122°F (50°C)
Maximum Operating Elevation: 9842.52 ft (3000000 mm)
Thermal Dissipation: 933 BTU/h
Physical Characteristics
Height: 6.97" (177 mm)
Width: 17.32" (440 mm)
Depth: 24.25" (616 mm)
Rack Height: 4U
Form Factor: Rack/Tower
Weight (Approximate): 60.70 kg
Miscellaneous
Package Contents:
  • SmartOnline SU3000LCD2UHVTF 3KVA Rack/Tower UPS
  • SU5000XFMRT2U20 2U 208V to 120V Step-Down Isolation Transformer
  • USB Cable
  • DB9 Cable
  • EPO Cable
  • Rack-mounting Hardware
  • Owner's Manual
Country of Origin: China
Environmentally Friendly: Yes
Environmental Compliance: Restriction of Hazardous Substances (RoHS)
Warranty
Limited Warranty: 2 Year
Stay ON Forever

Protects Your Device From Power Outage & Blackout

Express Shipping

Canada Wide Discounted Shipping

OEM Standard

Long Lasting Powerful Batteries with 1 year warranty

Hassle Free Returns

Request RMA and Get Refunded Within 3 Days

Technical Support

Get Free Technical Support & Installation Guide

Technical Support

Get Free Technical Support & Installation Guide

Tripp Lite by Eaton SmartOnline SU3000LCD2UHVTF 3KVA Rack/Tower UPS

UPC 0037332241719
4U Rack/Tower - 3 Hour Recharge - 5 Minute Stand-by - 230 V AC Input - 120 V AC, 208 V AC Output - Single Phase - Serial Port - 12 x NEMA 5-15/20R, 6 x NEMA 6-15/20R, 2 x NEMA L6-20R
General Information
Manufacturer: Tripp Lite by Eaton
Manufacturer Part Number: SU3000LCD2UHVTF
Manufacturer Website Address: https://tripplite.eaton.com/
Brand Name: Tripp Lite by Eaton
Product Line: SmartOnline
Product Model: SU3000LCD2UHVTF
Product Name: SmartOnline SU3000LCD2UHVTF 3KVA Rack/Tower UPS
Marketing Information:

2U Double-Conversion UPS Protects Equipment against Damage, Downtime and Data Loss

This 208V and 120V 60 Hz UPS system maintains perfect output by converting AC input to DC, then reconverting UPS output to fully regulated sine wave AC with +/-2% voltage regulation in both on-line and battery modes. Featuring a 2.7kW capacity, high 0.9 power factor, 570 joules of surge suppression, true on-line operation with pure sine wave output and zero transfer time in on-line double-conversion mode, the SmartOnline® SU3000LCD2UHVTF double-conversion UPS provides the highest level of AC power protection and battery backup for critical network closet, computer room and data center equipment. With the included 2U step-down transformer, this 3kVA UPS system can support both low- and high-voltage equipment.

Set Power Strategies to Reflect Your Protection Priorities

Pick your power strategy, from precise power for sensitive systems to the highest possible electrical efficiency, while ensuring 100% uptime. Choose from four selectable strategies: Max Efficiency, Max Quality, Frequency Regulation and Auto Adaptive, which automatically offers increased efficiency when utility power conditions are good and enhanced power quality when power conditions are poor.

Individually Controllable Load Banks Let You Access and Control Outlets Remotely

The UPS and transformer combined feature 20 outlets in total-12 unswitched NEMA 5-15/20R on the transformer, six NEMA 6-15/20R on the UPS and one unswitched NEMA L6-20R on each. Four NEMA 6-15/20R outlets are split into two switchable load banks, allowing you to reboot select components or shed loads remotely.

Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages

The field-replaceable, hot-swappable internal battery provides 13.5 minutes of support at half load (1350W) and five minutes at full load (2700W), keeping protected equipment operational through power failures. For mission-critical applications demanding scalable extended runtime, the UPS supports "smart" external battery packs, such as Tripp Lite's BP72V18-2US (sold separately). Both the internal batteries and sensor-enabled external battery packs are automatically sensed and configured during installation and replacement to offer accurate remaining runtime during outages and battery-age notifications. The intelligent battery management system with temperature-compensated charging extends battery life.

Automatic Bypass Maintains Utility Output During Fault Conditions

Auto-bypass mode keeps connected equipment powered and operational, even during UPS fault conditions.

Automatically Turns Back On When Power Is Restored

Battery-independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement.

Intuitive Front-Panel Interface for Convenient UPS Operation and Monitoring

The front-panel LCD screen reports UPS operating mode, detailed UPS status and site-power information, as well as a variety of advanced UPS setup and configuration options. LEDs indicate AC input/output, battery and fault status.

Advanced Communications Ports Allow for Automatic Saves and Shutdowns

RS-232 and HID-compliant USB ports connect to a computer running Tripp Lite's free downloadable PowerAlert® software to enable safe unattended file saves and system shutdown in case of a prolonged power failure. An EPO port connects the UPS to a contact closure switch to enable emergency inverter shutdown. Cables are included.

Product Type: Double Conversion Online UPS
Technical Information
Plug/Connector Type: NEMA L6-20P
Receptacle Type:
  • NEMA 5-15/20R
  • NEMA 6-15/20R
  • NEMA L6-20R
Receptacle Detail:
  • 12 x NEMA 5-15/20R
  • 6 x NEMA 6-15/20R
  • 2 x NEMA L6-20R
Transfer Time: 0 ns
EMI/RFI Noise Filter: Yes
Phase: Single Phase
Energy Saving: High Efficiency Economy Mode Operation; Individually Controllable Load Banks
Application/Usage:
  • Mission Critical Equipment
  • Server
  • Network Equipment
  • Data Center
  • Computer Room
  • Network Closet
Power Description
Load Capacity (VA): 3 kVA
Load Capacity (Watt): 2.70 kW
Input Voltage: 230 V AC
Output Voltage:
  • 120 V AC
  • 208 V AC
Output Frequency: 60 Hz
Waveform Type: Pure Sine Wave
Surge Energy Rating: 570 J
Management
Network Management: SNMP/DB9/USB
Alarm:
  • Power Failure
  • Low Battery
  • Overload
  • Fault
Controls/Indicators
Status Indicators:

4 Front Panel LEDs:

  • AC Input (Green)
  • AC Output (Green)
  • Battery (Yellow)
  • Fault (Red)
Interfaces/Ports
Serial Port: Yes
EPO Port: Yes
USB (HID Compliant) Port: Yes
Battery Information
DC System Voltage: 72 V DC
Backup/Run Time (Full Load): 5 Minute
Backup/Run Time (Half Load): 13.50 Minute
Typical Battery Recharge Time: 3 Hour
Hot Swappable: Yes
Replaceable Battery: Yes
Environmental Conditions
Maximum Operating Temperature: 104°F (40°C)
Storage Temperature: 5°F (-15°C) - 122°F (50°C)
Maximum Operating Elevation: 9842.52 ft (3000000 mm)
Thermal Dissipation: 933 BTU/h
Physical Characteristics
Height: 6.97" (177 mm)
Width: 17.32" (440 mm)
Depth: 24.25" (616 mm)
Rack Height: 4U
Form Factor: Rack/Tower
Weight (Approximate): 60.70 kg
Miscellaneous
Package Contents:
  • SmartOnline SU3000LCD2UHVTF 3KVA Rack/Tower UPS
  • SU5000XFMRT2U20 2U 208V to 120V Step-Down Isolation Transformer
  • USB Cable
  • DB9 Cable
  • EPO Cable
  • Rack-mounting Hardware
  • Owner's Manual
Country of Origin: China
Environmentally Friendly: Yes
Environmental Compliance: Restriction of Hazardous Substances (RoHS)
Warranty
Limited Warranty: 2 Year
Here is the Manual Guide

ORDER PROCESSING

We ship from Toronto to Worldwide.
We process orders within 1-2 business days (excluding weekends and holidays).
Pre-ordered items are processed within 2-3 business days of arrival in stock.

Successfully placed orders will receive an e-mail confirmation with the order details.
If you do not receive an e-mail, please check your spam filter or contact us for confirmation.

If you need any assistance with your order, please contact us immediately at support@upsandbattery.com. We will not be able to make changes to your order after it has shipped.

Please review and ensure that you have entered the correct address. We are not responsible for non-delivery due to errors in the address that you provide. If an order is returned due to an incorrect address, we will refund the original order (excluding the shipping fee) and ask that you re-submit your order.

Your credit card information is safe with us. We accept most major credit, debit, and prepaid cards, including Visa, MasterCard, American Express, Discover, JCB, and Diners Club International, PayPal, Google Pay and Apple Pay.