Tripp Lite by Eaton SmartOnline SUINT2000LCD1U 2000VA Rack-mountable UPS

UPC 0037332238153
1U Rack-mountable - 3 Minute Stand-by - 230 V AC Input - 200 V AC, 208 V AC, 230 V AC, 220 V AC, 240 V AC Output - Single Phase - Pure Sine Wave - Serial Port - USB - LCD Display - 5 x IEC 60320 C13
General Information
Manufacturer: Tripp Lite by Eaton
Manufacturer Part Number: SUINT2000LCD1U
Manufacturer Website Address: https://tripplite.eaton.com/
Brand Name: Tripp Lite by Eaton
Product Line: SmartOnline
Product Model: SUINT2000LCD1U
Product Name: SmartOnline SUINT2000LCD1U 2000VA Rack-mountable UPS
Marketing Information:

Double-Conversion UPS Protects Equipment Against Damage, Downtime and Data Loss

This 1U on-line double-conversion UPS system with battery-independent restart maintains perfect output by converting AC input to DC, then reconverting UPS output to fully regulated sine wave AC. Constant on-line operation completely isolates sensitive equipment from every power problem on the AC line. The SmartOnline® SUINT2000LCD1U provides the highest level of power protection and battery backup for servers, switches, phone systems, kiosks and professional A/V computer systems in IT applications where rack space is limited and a 1U UPS is desired.

Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages

The field-replaceable, hot-swappable VRLA internal battery allows you to work through short power failures and give you enough time to safely save files and shut down your system in case of a prolonged blackout. Zero transfer time between on-line and battery modes maintains continuous operation of connected equipment without interruption or rebooting.

Optional LX Platform Network Management Card Allows Remote Access 24/7

The WEBCARDLXE network interface (sold separately) enables full remote configuration and management, including load shedding, reboots of connected equipment and safe shutdowns. The IP-based Auto Probe feature ensures continuous network uptime by communicating with other network devices, detecting lost connectivity and automatically rebooting IT equipment. Optional EnviroSense2 modules (E2MT, E2MTDO and E2MTHDI, all sold separately) provide a variety of environmental monitoring and control options.

C13 Outlets Protect Your Connected Components

Five C13 outlets provide connected equipment with pure sine wave AC output and allow you to monitor power consumption down to the outlet group level. Power provided by these outlets is filtered to protect connected equipment against damaging surges and line noise. The outlets are grouped into two individually controllable load banks that let you shed non-critical loads to extend runtime for critical loads.

Premium Protection from EMI/RFI Line Noise Helps Your Equipment Perform Better

This UPS system filters out disruptive electromagnetic and radio frequency interference that can inflict hardware damage or data loss. This EMI/RFI filtering also helps your connected components perform better and last longer.

Clear LCD Interface Keeps You Informed at a Glance

The menu-driven front-panel LCD provides detailed settings, alarms and notifications to help diagnose any issues. It provides voltage, frequency, battery, load and other critical information. Audible alarms can be disabled through the front menu when the UPS goes to battery power. LEDs indicate AC output status and shutdown/fault condition.

Advanced Communications Ports Allow for Automatic Saves and Shutdowns

RS-232 and USB ports connect to a device for a variety of communication options (cables are included). A dry-contact relay port can be programmed through the LCD to provide reliable communications to automation and industrial components. The EPO/ROO port permits emergency shutdown or remote restart of all connected equipment.

Needs Only 1U of Rack Space for Installation

You can mount the SUINT2000LCD1U in just 1U of space in an EIA-standard 19-inch 4-post rack using the included hardware. The six-foot (1.8-meter) power cord with C14 plug connects to a compatible AC outlet. An internal fan helps keep the UPS cool in a crowded enclosure.

Product Type: Double Conversion Online UPS
Technical Information
Plug/Connector Type: IEC 60320 C14
Receptacle Type: IEC 60320 C13
Receptacle Detail: 5 x IEC 60320 C13
EMI/RFI Noise Filter: Yes
Phase: Single Phase
Energy Saving: Green Energy-Saving
Application/Usage:
  • Mission Critical Equipment
  • IT
  • Server
  • Switch
  • Phone
  • Kiosk
  • Data Center
  • Computer Room
  • Industrial
  • Automation Industry
  • Network Equipment
Power Description
Load Capacity (VA): 2 kVA
Load Capacity (Watt): 1.60 kW
Input Voltage: 230 V AC
Output Voltage:
  • 200 V AC
  • 208 V AC
  • 230 V AC
  • 220 V AC
  • 240 V AC
Input Frequency: 60 Hz
Output Frequency: 60 Hz
Waveform Type: Pure Sine Wave
Surge Energy Rating: 540 J
Output Power Factor: 0.8
Display & Graphics
Display: LCD
Management
Network Management:
  • SNMP/Web
  • DB-9 RS-232
Alarm:
  • Power Failure
  • Low Battery
  • Overload
  • Fault
Controls/Indicators
Status Indicators:

LED Indicators:

  • AC Output
  • Shutdown / Fault
Interfaces/Ports
Serial Port: Yes
USB: Yes
EPO Port: Yes
USB (HID Compliant) Port: Yes
Battery Information
DC System Voltage: 48 V DC
Battery Characteristics: Valve-regulated
Battery Chemistry: Lead Acid
Backup/Run Time (Full Load): 3 Minute
Backup/Run Time (Half Load): 10 Minute
Hot Swappable: Yes
Replaceable Battery: Yes
Environmental Conditions
Minimum Operating Temperature: 32°F (0°C)
Maximum Operating Temperature: 104°F (40°C)
Storage Temperature: 5°F (-15°C) - 122°F (50°C)
Maximum Operating Elevation: 3280.84 ft (1000000 mm)
Sound Emission (A-Weighted): 65 dB(A)
Thermal Dissipation: 888 BTU/h
Physical Characteristics
Height: 1.73" (43.94 mm)
Width: 17.32" (439.93 mm)
Depth: 27.95" (709.93 mm)
Rack Height: 1U
Form Factor: Rack-mountable
Weight (Approximate): 22 kg
Miscellaneous
Package Contents:
  • SmartOnline SUINT2000LCD1U 2000VA Rack-mountable UPS
  • USB Cable
  • DB9 Cable
  • Rack-mounting Hardware
  • Owner's Manual
  • Back Panel Grounding Lug
Environmentally Friendly: Yes
Environmental Compliance: Restriction of Hazardous Substances (RoHS)
Warranty
Limited Warranty: 2 Year
Stay ON Forever

Protects Your Device From Power Outage & Blackout

Express Shipping

Canada Wide Discounted Shipping

OEM Standard

Long Lasting Powerful Batteries with 1 year warranty

Hassle Free Returns

Request RMA and Get Refunded Within 3 Days

Technical Support

Get Free Technical Support & Installation Guide

Technical Support

Get Free Technical Support & Installation Guide

Tripp Lite by Eaton SmartOnline SUINT2000LCD1U 2000VA Rack-mountable UPS

UPC 0037332238153
1U Rack-mountable - 3 Minute Stand-by - 230 V AC Input - 200 V AC, 208 V AC, 230 V AC, 220 V AC, 240 V AC Output - Single Phase - Pure Sine Wave - Serial Port - USB - LCD Display - 5 x IEC 60320 C13
General Information
Manufacturer: Tripp Lite by Eaton
Manufacturer Part Number: SUINT2000LCD1U
Manufacturer Website Address: https://tripplite.eaton.com/
Brand Name: Tripp Lite by Eaton
Product Line: SmartOnline
Product Model: SUINT2000LCD1U
Product Name: SmartOnline SUINT2000LCD1U 2000VA Rack-mountable UPS
Marketing Information:

Double-Conversion UPS Protects Equipment Against Damage, Downtime and Data Loss

This 1U on-line double-conversion UPS system with battery-independent restart maintains perfect output by converting AC input to DC, then reconverting UPS output to fully regulated sine wave AC. Constant on-line operation completely isolates sensitive equipment from every power problem on the AC line. The SmartOnline® SUINT2000LCD1U provides the highest level of power protection and battery backup for servers, switches, phone systems, kiosks and professional A/V computer systems in IT applications where rack space is limited and a 1U UPS is desired.

Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages

The field-replaceable, hot-swappable VRLA internal battery allows you to work through short power failures and give you enough time to safely save files and shut down your system in case of a prolonged blackout. Zero transfer time between on-line and battery modes maintains continuous operation of connected equipment without interruption or rebooting.

Optional LX Platform Network Management Card Allows Remote Access 24/7

The WEBCARDLXE network interface (sold separately) enables full remote configuration and management, including load shedding, reboots of connected equipment and safe shutdowns. The IP-based Auto Probe feature ensures continuous network uptime by communicating with other network devices, detecting lost connectivity and automatically rebooting IT equipment. Optional EnviroSense2 modules (E2MT, E2MTDO and E2MTHDI, all sold separately) provide a variety of environmental monitoring and control options.

C13 Outlets Protect Your Connected Components

Five C13 outlets provide connected equipment with pure sine wave AC output and allow you to monitor power consumption down to the outlet group level. Power provided by these outlets is filtered to protect connected equipment against damaging surges and line noise. The outlets are grouped into two individually controllable load banks that let you shed non-critical loads to extend runtime for critical loads.

Premium Protection from EMI/RFI Line Noise Helps Your Equipment Perform Better

This UPS system filters out disruptive electromagnetic and radio frequency interference that can inflict hardware damage or data loss. This EMI/RFI filtering also helps your connected components perform better and last longer.

Clear LCD Interface Keeps You Informed at a Glance

The menu-driven front-panel LCD provides detailed settings, alarms and notifications to help diagnose any issues. It provides voltage, frequency, battery, load and other critical information. Audible alarms can be disabled through the front menu when the UPS goes to battery power. LEDs indicate AC output status and shutdown/fault condition.

Advanced Communications Ports Allow for Automatic Saves and Shutdowns

RS-232 and USB ports connect to a device for a variety of communication options (cables are included). A dry-contact relay port can be programmed through the LCD to provide reliable communications to automation and industrial components. The EPO/ROO port permits emergency shutdown or remote restart of all connected equipment.

Needs Only 1U of Rack Space for Installation

You can mount the SUINT2000LCD1U in just 1U of space in an EIA-standard 19-inch 4-post rack using the included hardware. The six-foot (1.8-meter) power cord with C14 plug connects to a compatible AC outlet. An internal fan helps keep the UPS cool in a crowded enclosure.

Product Type: Double Conversion Online UPS
Technical Information
Plug/Connector Type: IEC 60320 C14
Receptacle Type: IEC 60320 C13
Receptacle Detail: 5 x IEC 60320 C13
EMI/RFI Noise Filter: Yes
Phase: Single Phase
Energy Saving: Green Energy-Saving
Application/Usage:
  • Mission Critical Equipment
  • IT
  • Server
  • Switch
  • Phone
  • Kiosk
  • Data Center
  • Computer Room
  • Industrial
  • Automation Industry
  • Network Equipment
Power Description
Load Capacity (VA): 2 kVA
Load Capacity (Watt): 1.60 kW
Input Voltage: 230 V AC
Output Voltage:
  • 200 V AC
  • 208 V AC
  • 230 V AC
  • 220 V AC
  • 240 V AC
Input Frequency: 60 Hz
Output Frequency: 60 Hz
Waveform Type: Pure Sine Wave
Surge Energy Rating: 540 J
Output Power Factor: 0.8
Display & Graphics
Display: LCD
Management
Network Management:
  • SNMP/Web
  • DB-9 RS-232
Alarm:
  • Power Failure
  • Low Battery
  • Overload
  • Fault
Controls/Indicators
Status Indicators:

LED Indicators:

  • AC Output
  • Shutdown / Fault
Interfaces/Ports
Serial Port: Yes
USB: Yes
EPO Port: Yes
USB (HID Compliant) Port: Yes
Battery Information
DC System Voltage: 48 V DC
Battery Characteristics: Valve-regulated
Battery Chemistry: Lead Acid
Backup/Run Time (Full Load): 3 Minute
Backup/Run Time (Half Load): 10 Minute
Hot Swappable: Yes
Replaceable Battery: Yes
Environmental Conditions
Minimum Operating Temperature: 32°F (0°C)
Maximum Operating Temperature: 104°F (40°C)
Storage Temperature: 5°F (-15°C) - 122°F (50°C)
Maximum Operating Elevation: 3280.84 ft (1000000 mm)
Sound Emission (A-Weighted): 65 dB(A)
Thermal Dissipation: 888 BTU/h
Physical Characteristics
Height: 1.73" (43.94 mm)
Width: 17.32" (439.93 mm)
Depth: 27.95" (709.93 mm)
Rack Height: 1U
Form Factor: Rack-mountable
Weight (Approximate): 22 kg
Miscellaneous
Package Contents:
  • SmartOnline SUINT2000LCD1U 2000VA Rack-mountable UPS
  • USB Cable
  • DB9 Cable
  • Rack-mounting Hardware
  • Owner's Manual
  • Back Panel Grounding Lug
Environmentally Friendly: Yes
Environmental Compliance: Restriction of Hazardous Substances (RoHS)
Warranty
Limited Warranty: 2 Year
Here is the Manual Guide

ORDER PROCESSING

We ship from Toronto to Worldwide.
We process orders within 1-2 business days (excluding weekends and holidays).
Pre-ordered items are processed within 2-3 business days of arrival in stock.

Successfully placed orders will receive an e-mail confirmation with the order details.
If you do not receive an e-mail, please check your spam filter or contact us for confirmation.

If you need any assistance with your order, please contact us immediately at support@upsandbattery.com. We will not be able to make changes to your order after it has shipped.

Please review and ensure that you have entered the correct address. We are not responsible for non-delivery due to errors in the address that you provide. If an order is returned due to an incorrect address, we will refund the original order (excluding the shipping fee) and ask that you re-submit your order.

Your credit card information is safe with us. We accept most major credit, debit, and prepaid cards, including Visa, MasterCard, American Express, Discover, JCB, and Diners Club International, PayPal, Google Pay and Apple Pay.