Tripp Lite by Eaton Monitored PDUMNH30 16-Outlets PDU - PDUMNH30 - PDU, 120 V AC, 2U, 120 V AC, NEMA L5-30P, Monitored

Tripp Lite by Eaton Monitored PDUMNH30 16-Outlets PDU - PDUMNH30 - PDU, 120 V AC, 2U, 120 V AC, NEMA L5-30P, Monitored

$987.52 $2,038.60
Availability:
Out of stock
Product type:
Product Features:
  • Brand: Tripp Lite by Eaton
  • Product Type: PDU
  • Manufacturer Part Number: PDUMNH30
  • Input Voltage: 120 V AC
  • Rack Height: 2U
  • Plug/Connector Type: NEMA L5-30P
  • Product Family: Monitored

  • Marketing Information: 2.9kW Single-Phase Monitored PDU with LX Platform Interface

    Tripp Lite's PDUMNH30 distributes and monitors single-phase 120V power to connected rack equipment in data centers, network closets, server rooms, computer rooms and other applications requiring network-grade power. Its built-in network interface allows real-time remote monitoring of voltage, frequency and load levels to prevent overloads that cause expensive downtime. It features 16 NEMA 5-15/20R outlets and a 10-foot (3-meter) power cord with NEMA L5-30P plug, which connects the PDU to a compatible AC power source, generator or protected UPS system.

    Built-In LX Platform Network Management Interface Card

    The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities, including temperature and humidity conditions. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. DHCP/Manual configuration lets you assign network settings to the card automatically, reducing the need for manual configuration. Automated alerts help prevent accidental overloads, power loss and downtime.

    Digital Load Meter

    The easy-to-read two-character digital LED meter displays output load levels in three segments: breakered bank 1, breakered bank 2 and total PDU output. Monitoring the individual breakered load banks helps ensure proper balance across the two output load banks. Monitoring total PDU output helps prevent PDU and supply circuit overloads that cause downtime.

    Optimized for Demanding Applications

    The all-metal housing is designed to endure in busy, demanding IT and industrial environments. The included cord retention brackets for the outlets help prevent connected equipment from becoming accidentally disconnected. Real-time clock backup maintains the time of day and date, even if the PDU is shut down and unpowered.

    Versatile Installation Options

    This server rack PDU features a 2U horizontal rack-mount form factor. Mounting flanges support installation in 2- and 4-post racks, with additional support for wall-mount and under-counter installation. Mounting ears are reversible for front- or rear-facing rack-mount installation.

    TAA-Compliant for GSA Schedule Purchases

    The PDUMNH30 monitored power distribution unit is compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases.

    2-Year Warranty and Environmentally Responsible Design

    This monitored PDU comes with a 2-year limited warranty. It's manufactured in compliance with strict RoHS specifications, reflecting Tripp Lite's commitment to environmental responsibility.

    More from the Manufacturer

Product Specifications:
Product Features:
  • Manufacturer:Eaton Corporation
  • Manufacturer Part Number:PDUMNH30
  • Manufacturer Website Address:https://tripplite.eaton.com/
  • Brand Name:Tripp Lite by Eaton
  • Product Series:Monitored
  • Product Model:PDUMNH30
  • Product Name:Monitored PDUMNH30 16-Outlets PDU

  • Marketing Information:2.9kW Single-Phase Monitored PDU with LX Platform Interface

    Tripp Lite's PDUMNH30 distributes and monitors single-phase 120V power to connected rack equipment in data centers, network closets, server rooms, computer rooms and other applications requiring network-grade power. Its built-in network interface allows real-time remote monitoring of voltage, frequency and load levels to prevent overloads that cause expensive downtime. It features 16 NEMA 5-15/20R outlets and a 10-foot (3-meter) power cord with NEMA L5-30P plug, which connects the PDU to a compatible AC power source, generator or protected UPS system.

    Built-In LX Platform Network Management Interface Card

    The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities, including temperature and humidity conditions. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. DHCP/Manual configuration lets you assign network settings to the card automatically, reducing the need for manual configuration. Automated alerts help prevent accidental overloads, power loss and downtime.

    Digital Load Meter

    The easy-to-read two-character digital LED meter displays output load levels in three segments: breakered bank 1, breakered bank 2 and total PDU output. Monitoring the individual breakered load banks helps ensure proper balance across the two output load banks. Monitoring total PDU output helps prevent PDU and supply circuit overloads that cause downtime.

    Optimized for Demanding Applications

    The all-metal housing is designed to endure in busy, demanding IT and industrial environments. The included cord retention brackets for the outlets help prevent connected equipment from becoming accidentally disconnected. Real-time clock backup maintains the time of day and date, even if the PDU is shut down and unpowered.

    Versatile Installation Options

    This server rack PDU features a 2U horizontal rack-mount form factor. Mounting flanges support installation in 2- and 4-post racks, with additional support for wall-mount and under-counter installation. Mounting ears are reversible for front- or rear-facing rack-mount installation.

    TAA-Compliant for GSA Schedule Purchases

    The PDUMNH30 monitored power distribution unit is compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases.

    2-Year Warranty and Environmentally Responsible Design

    This monitored PDU comes with a 2-year limited warranty. It's manufactured in compliance with strict RoHS specifications, reflecting Tripp Lite's commitment to environmental responsibility.
    PRODUCT SPECIFICATIONS
    PDU Type Monitored
    Plug/Connector Type NEMA L5-30P
    Receptacle Type NEMA 5-15/20R
    Receptacle Detail 16 x NEMA 5-15/20R
    Protection Type Overload Protection
    Input Voltage 120 V AC
    Output Voltage 120 V AC
    Management

    Protocols:

    • HTTP
    • HTTPS
    • SMTP
    • SNMPv1
    • SNMPv2
    • Telnet
    • FTP
    • DHCP
    • BOOTP
    • NTP
    Mount Type Rack-mountable
    Rack Height 2U
    Height 3.50" (88.90 mm)
    Width 17.50" (444.50 mm)
    Depth 12.50" (317.50 mm)
    Weight (Approximate) 13.80 lb (6259.57 g)
    Package Contents
    • Monitored PDUMNH30 16-Outlets PDU
    • Plug Retention Plates
    • Rack Mounting Brackets
    • Owner's Manual
    Country of Origin Taiwan
    TAA Compliant Yes
    Environmentally Friendly Yes
    Environmental Compliance Restriction of Hazardous Substances (RoHS)
    Limited Warranty 2 Year
    Stay ON Forever

    Protects Your Device From Power Outage & Blackout

    Express Shipping

    Canada Wide Discounted Shipping

    OEM Standard

    Long Lasting Powerful Batteries with 1 year warranty

    Hassle Free Returns

    Request RMA and Get Refunded Within 3 Days

    Technical Support

    Get Free Technical Support & Installation Guide

    Technical Support

    Get Free Technical Support & Installation Guide

    Product Features:
    • Brand: Tripp Lite by Eaton
    • Product Type: PDU
    • Manufacturer Part Number: PDUMNH30
    • Input Voltage: 120 V AC
    • Rack Height: 2U
    • Plug/Connector Type: NEMA L5-30P
    • Product Family: Monitored

    • Marketing Information: 2.9kW Single-Phase Monitored PDU with LX Platform Interface

      Tripp Lite's PDUMNH30 distributes and monitors single-phase 120V power to connected rack equipment in data centers, network closets, server rooms, computer rooms and other applications requiring network-grade power. Its built-in network interface allows real-time remote monitoring of voltage, frequency and load levels to prevent overloads that cause expensive downtime. It features 16 NEMA 5-15/20R outlets and a 10-foot (3-meter) power cord with NEMA L5-30P plug, which connects the PDU to a compatible AC power source, generator or protected UPS system.

      Built-In LX Platform Network Management Interface Card

      The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities, including temperature and humidity conditions. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. DHCP/Manual configuration lets you assign network settings to the card automatically, reducing the need for manual configuration. Automated alerts help prevent accidental overloads, power loss and downtime.

      Digital Load Meter

      The easy-to-read two-character digital LED meter displays output load levels in three segments: breakered bank 1, breakered bank 2 and total PDU output. Monitoring the individual breakered load banks helps ensure proper balance across the two output load banks. Monitoring total PDU output helps prevent PDU and supply circuit overloads that cause downtime.

      Optimized for Demanding Applications

      The all-metal housing is designed to endure in busy, demanding IT and industrial environments. The included cord retention brackets for the outlets help prevent connected equipment from becoming accidentally disconnected. Real-time clock backup maintains the time of day and date, even if the PDU is shut down and unpowered.

      Versatile Installation Options

      This server rack PDU features a 2U horizontal rack-mount form factor. Mounting flanges support installation in 2- and 4-post racks, with additional support for wall-mount and under-counter installation. Mounting ears are reversible for front- or rear-facing rack-mount installation.

      TAA-Compliant for GSA Schedule Purchases

      The PDUMNH30 monitored power distribution unit is compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases.

      2-Year Warranty and Environmentally Responsible Design

      This monitored PDU comes with a 2-year limited warranty. It's manufactured in compliance with strict RoHS specifications, reflecting Tripp Lite's commitment to environmental responsibility.

      More from the Manufacturer

    Product Specifications:
    Product Features:
  • Manufacturer:Eaton Corporation
  • Manufacturer Part Number:PDUMNH30
  • Manufacturer Website Address:https://tripplite.eaton.com/
  • Brand Name:Tripp Lite by Eaton
  • Product Series:Monitored
  • Product Model:PDUMNH30
  • Product Name:Monitored PDUMNH30 16-Outlets PDU

  • Marketing Information:2.9kW Single-Phase Monitored PDU with LX Platform Interface

    Tripp Lite's PDUMNH30 distributes and monitors single-phase 120V power to connected rack equipment in data centers, network closets, server rooms, computer rooms and other applications requiring network-grade power. Its built-in network interface allows real-time remote monitoring of voltage, frequency and load levels to prevent overloads that cause expensive downtime. It features 16 NEMA 5-15/20R outlets and a 10-foot (3-meter) power cord with NEMA L5-30P plug, which connects the PDU to a compatible AC power source, generator or protected UPS system.

    Built-In LX Platform Network Management Interface Card

    The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities, including temperature and humidity conditions. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. DHCP/Manual configuration lets you assign network settings to the card automatically, reducing the need for manual configuration. Automated alerts help prevent accidental overloads, power loss and downtime.

    Digital Load Meter

    The easy-to-read two-character digital LED meter displays output load levels in three segments: breakered bank 1, breakered bank 2 and total PDU output. Monitoring the individual breakered load banks helps ensure proper balance across the two output load banks. Monitoring total PDU output helps prevent PDU and supply circuit overloads that cause downtime.

    Optimized for Demanding Applications

    The all-metal housing is designed to endure in busy, demanding IT and industrial environments. The included cord retention brackets for the outlets help prevent connected equipment from becoming accidentally disconnected. Real-time clock backup maintains the time of day and date, even if the PDU is shut down and unpowered.

    Versatile Installation Options

    This server rack PDU features a 2U horizontal rack-mount form factor. Mounting flanges support installation in 2- and 4-post racks, with additional support for wall-mount and under-counter installation. Mounting ears are reversible for front- or rear-facing rack-mount installation.

    TAA-Compliant for GSA Schedule Purchases

    The PDUMNH30 monitored power distribution unit is compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases.

    2-Year Warranty and Environmentally Responsible Design

    This monitored PDU comes with a 2-year limited warranty. It's manufactured in compliance with strict RoHS specifications, reflecting Tripp Lite's commitment to environmental responsibility.
    PRODUCT SPECIFICATIONS
    PDU Type Monitored
    Plug/Connector Type NEMA L5-30P
    Receptacle Type NEMA 5-15/20R
    Receptacle Detail 16 x NEMA 5-15/20R
    Protection Type Overload Protection
    Input Voltage 120 V AC
    Output Voltage 120 V AC
    Management

    Protocols:

    • HTTP
    • HTTPS
    • SMTP
    • SNMPv1
    • SNMPv2
    • Telnet
    • FTP
    • DHCP
    • BOOTP
    • NTP
    Mount Type Rack-mountable
    Rack Height 2U
    Height 3.50" (88.90 mm)
    Width 17.50" (444.50 mm)
    Depth 12.50" (317.50 mm)
    Weight (Approximate) 13.80 lb (6259.57 g)
    Package Contents
    • Monitored PDUMNH30 16-Outlets PDU
    • Plug Retention Plates
    • Rack Mounting Brackets
    • Owner's Manual
    Country of Origin Taiwan
    TAA Compliant Yes
    Environmentally Friendly Yes
    Environmental Compliance Restriction of Hazardous Substances (RoHS)
    Limited Warranty 2 Year
    Here is the Manual Guide

    ORDER PROCESSING

    We ship from Toronto to Worldwide.
    We process orders within 1-2 business days (excluding weekends and holidays).
    Pre-ordered items are processed within 2-3 business days of arrival in stock.

    Successfully placed orders will receive an e-mail confirmation with the order details.
    If you do not receive an e-mail, please check your spam filter or contact us for confirmation.

    If you need any assistance with your order, please contact us immediately at support@upsandbattery.com. We will not be able to make changes to your order after it has shipped.

    Please review and ensure that you have entered the correct address. We are not responsible for non-delivery due to errors in the address that you provide. If an order is returned due to an incorrect address, we will refund the original order (excluding the shipping fee) and ask that you re-submit your order.