Tripp Lite UPS Maintenance Bypass Panel for SUTX40K - 3 Breakers - SUT40KMBPX - Bypass Panel, 400 V AC,230 V AC, Wall-mountable, Hard Wire 4-wire (3P + N + E)

Tripp Lite UPS Maintenance Bypass Panel for SUTX40K - 3 Breakers - SUT40KMBPX - Bypass Panel, 400 V AC,230 V AC, Wall-mountable, Hard Wire 4-wire (3P + N + E)

$4,645.63 $9,278.75
Availability:
Out of stock
Product type:
Vendor:
Product Features:
  • Brand: Tripp Lite
  • Product Type: Bypass Panel
  • Manufacturer Part Number: SUT40KMBPX
  • Input Voltage: 400 V AC,230 V AC
  • Form Factor: Wall-mountable
  • Plug/Connector Type: Hard Wire 4-wire (3P + N + E)

  • Marketing Information:

    UPS Maintenance Bypass Panel Keeps Equipment Powered During UPS Maintenance

    This wall-mount three-breaker maintenance bypass panel is compatible with Tripp Lite's SUTX40K 3-phase UPS system. It allows you to reroute power around the UPS, providing an alternate path for electricity that keeps the connected load operational while the UPS is offline for maintenance or repairs.

    Features 3 Built-In Circuit Breakers to Isolate Loads

    Three 4-pole circuit breakers - an AC input breaker, a maintenance bypass breaker and a maintenance isolation breaker - are connected to heavy-duty buswork and isolate the UPS system from its connected load with no loss of network availability. This allows the load to remain continuously powered without costly downtime. A Kirk-key interlock system enhances safety and security. Removable handles allow the panel's trim cover to be removed for internal access. The 125A unit has a kAIC rating of 10K.

    Switching Between Normal and Bypass Modes Is Easy

    When a UPS needs maintenance, this UPS bypass panel keeps power supplied to components via its mechanical interlock system by switching power to the external bypass breaker. Simply unscrew the interlock switch, rotate the switch from the UPS AC input breaker (SW1) to the bypass breaker (SW2), then turn on the bypass breaker and turn off the UPS and isolation breaker (SW3) to perform UPS maintenance without service interruption.

    Convenient Wall-Mount Installation

    Made of galvanized steel, the service bypass panel has rear mounting holes for installation on a smooth, solid wall (mounting hardware not included).

Product Specifications:
Product Features:
  • Manufacturer:Tripp Lite by Eaton
  • Manufacturer Part Number:SUT40KMBPX
  • Manufacturer Website Address:https://tripplite.eaton.com/
  • Brand Name:Tripp Lite
  • Product Model:SUT40KMBPX
  • Product Name:UPS Maintenance Bypass Panel for SUTX40K - 3 Breakers

  • Marketing Information:

    UPS Maintenance Bypass Panel Keeps Equipment Powered During UPS Maintenance

    This wall-mount three-breaker maintenance bypass panel is compatible with Tripp Lite's SUTX40K 3-phase UPS system. It allows you to reroute power around the UPS, providing an alternate path for electricity that keeps the connected load operational while the UPS is offline for maintenance or repairs.

    Features 3 Built-In Circuit Breakers to Isolate Loads

    Three 4-pole circuit breakers - an AC input breaker, a maintenance bypass breaker and a maintenance isolation breaker - are connected to heavy-duty buswork and isolate the UPS system from its connected load with no loss of network availability. This allows the load to remain continuously powered without costly downtime. A Kirk-key interlock system enhances safety and security. Removable handles allow the panel's trim cover to be removed for internal access. The 125A unit has a kAIC rating of 10K.

    Switching Between Normal and Bypass Modes Is Easy

    When a UPS needs maintenance, this UPS bypass panel keeps power supplied to components via its mechanical interlock system by switching power to the external bypass breaker. Simply unscrew the interlock switch, rotate the switch from the UPS AC input breaker (SW1) to the bypass breaker (SW2), then turn on the bypass breaker and turn off the UPS and isolation breaker (SW3) to perform UPS maintenance without service interruption.

    Convenient Wall-Mount Installation

    Made of galvanized steel, the service bypass panel has rear mounting holes for installation on a smooth, solid wall (mounting hardware not included).


    PRODUCT SPECIFICATIONS
    Plug/Connector Type Hard Wire 4-wire (3P + N + E)
    Input Voltage
    • 400 V AC
    • 230 V AC
    Current 125 A
    Form Factor Wall-mountable
    Height 17.50" (444.50 mm)
    Width 20" (508 mm)
    Depth 4.60" (116.80 mm)
    Weight (Approximate) 9.07 kg
    Package Contents
    • UPS Maintenance Bypass Panel for SUTX40K - 3 Breakers
    • Installation and Operation Manual
    Compatibility Tripp Lite SUTX40K 3-phase UPS System
    Environmentally Friendly Yes
    Country of Origin United States
    TAA Compliant Yes
    Limited Warranty 1 Year
    Stay ON Forever

    Protects Your Device From Power Outage & Blackout

    Express Shipping

    Canada Wide Discounted Shipping

    OEM Standard

    Long Lasting Powerful Batteries with 1 year warranty

    Hassle Free Returns

    Request RMA and Get Refunded Within 3 Days

    Technical Support

    Get Free Technical Support & Installation Guide

    Technical Support

    Get Free Technical Support & Installation Guide

    Product Features:
    • Brand: Tripp Lite
    • Product Type: Bypass Panel
    • Manufacturer Part Number: SUT40KMBPX
    • Input Voltage: 400 V AC,230 V AC
    • Form Factor: Wall-mountable
    • Plug/Connector Type: Hard Wire 4-wire (3P + N + E)

    • Marketing Information:

      UPS Maintenance Bypass Panel Keeps Equipment Powered During UPS Maintenance

      This wall-mount three-breaker maintenance bypass panel is compatible with Tripp Lite's SUTX40K 3-phase UPS system. It allows you to reroute power around the UPS, providing an alternate path for electricity that keeps the connected load operational while the UPS is offline for maintenance or repairs.

      Features 3 Built-In Circuit Breakers to Isolate Loads

      Three 4-pole circuit breakers - an AC input breaker, a maintenance bypass breaker and a maintenance isolation breaker - are connected to heavy-duty buswork and isolate the UPS system from its connected load with no loss of network availability. This allows the load to remain continuously powered without costly downtime. A Kirk-key interlock system enhances safety and security. Removable handles allow the panel's trim cover to be removed for internal access. The 125A unit has a kAIC rating of 10K.

      Switching Between Normal and Bypass Modes Is Easy

      When a UPS needs maintenance, this UPS bypass panel keeps power supplied to components via its mechanical interlock system by switching power to the external bypass breaker. Simply unscrew the interlock switch, rotate the switch from the UPS AC input breaker (SW1) to the bypass breaker (SW2), then turn on the bypass breaker and turn off the UPS and isolation breaker (SW3) to perform UPS maintenance without service interruption.

      Convenient Wall-Mount Installation

      Made of galvanized steel, the service bypass panel has rear mounting holes for installation on a smooth, solid wall (mounting hardware not included).

    Product Specifications:
    Product Features:
  • Manufacturer:Tripp Lite by Eaton
  • Manufacturer Part Number:SUT40KMBPX
  • Manufacturer Website Address:https://tripplite.eaton.com/
  • Brand Name:Tripp Lite
  • Product Model:SUT40KMBPX
  • Product Name:UPS Maintenance Bypass Panel for SUTX40K - 3 Breakers

  • Marketing Information:

    UPS Maintenance Bypass Panel Keeps Equipment Powered During UPS Maintenance

    This wall-mount three-breaker maintenance bypass panel is compatible with Tripp Lite's SUTX40K 3-phase UPS system. It allows you to reroute power around the UPS, providing an alternate path for electricity that keeps the connected load operational while the UPS is offline for maintenance or repairs.

    Features 3 Built-In Circuit Breakers to Isolate Loads

    Three 4-pole circuit breakers - an AC input breaker, a maintenance bypass breaker and a maintenance isolation breaker - are connected to heavy-duty buswork and isolate the UPS system from its connected load with no loss of network availability. This allows the load to remain continuously powered without costly downtime. A Kirk-key interlock system enhances safety and security. Removable handles allow the panel's trim cover to be removed for internal access. The 125A unit has a kAIC rating of 10K.

    Switching Between Normal and Bypass Modes Is Easy

    When a UPS needs maintenance, this UPS bypass panel keeps power supplied to components via its mechanical interlock system by switching power to the external bypass breaker. Simply unscrew the interlock switch, rotate the switch from the UPS AC input breaker (SW1) to the bypass breaker (SW2), then turn on the bypass breaker and turn off the UPS and isolation breaker (SW3) to perform UPS maintenance without service interruption.

    Convenient Wall-Mount Installation

    Made of galvanized steel, the service bypass panel has rear mounting holes for installation on a smooth, solid wall (mounting hardware not included).


    PRODUCT SPECIFICATIONS
    Plug/Connector Type Hard Wire 4-wire (3P + N + E)
    Input Voltage
    • 400 V AC
    • 230 V AC
    Current 125 A
    Form Factor Wall-mountable
    Height 17.50" (444.50 mm)
    Width 20" (508 mm)
    Depth 4.60" (116.80 mm)
    Weight (Approximate) 9.07 kg
    Package Contents
    • UPS Maintenance Bypass Panel for SUTX40K - 3 Breakers
    • Installation and Operation Manual
    Compatibility Tripp Lite SUTX40K 3-phase UPS System
    Environmentally Friendly Yes
    Country of Origin United States
    TAA Compliant Yes
    Limited Warranty 1 Year
    Here is the Manual Guide

    ORDER PROCESSING

    We ship from Toronto to Worldwide.
    We process orders within 1-2 business days (excluding weekends and holidays).
    Pre-ordered items are processed within 2-3 business days of arrival in stock.

    Successfully placed orders will receive an e-mail confirmation with the order details.
    If you do not receive an e-mail, please check your spam filter or contact us for confirmation.

    If you need any assistance with your order, please contact us immediately at support@upsandbattery.com. We will not be able to make changes to your order after it has shipped.

    Please review and ensure that you have entered the correct address. We are not responsible for non-delivery due to errors in the address that you provide. If an order is returned due to an incorrect address, we will refund the original order (excluding the shipping fee) and ask that you re-submit your order.

    Your credit card information is safe with us. We accept most major credit, debit, and prepaid cards, including Visa, MasterCard, American Express, Discover, JCB, and Diners Club International, PayPal, Google Pay and Apple Pay.